Skip to main content
3D Imaging Systems (CBCT)
  • 4-in-1 Digital X-Ray System (Pano, Ceph, CBCT, Model Scan)
  • Multi FOV Selection: 4×4 up to 18×15 cm for Comprehensive Diagnostics
  • Ultra-Fast Green Scan Time: Ceph 1.9s, CBCT 2.9s, Pano 4.0s
  • Endo Mode with High Resolution: 4×4 cm at 50-Micron (0.05 mm) Voxel Size
  • Insight 2.0 Feature with Upgraded Free FOV Layered Navigation
  • 3D Scanning for Model with Stable Protective Jig
Green X 18 Hardware Equipment

Green X 18

MAXIMIZE YOUR POTENTIAL TOWARDS SUCCESS

DESCRIPTION

Multi-FOV Anatomical Scope: 40mm to 210mm

VERSATILE MULTI FOV SELECTION (4×4 TO 18×15 CM)

Green X 18 offers a comprehensive range of selectable fields of view. The Multi FOV option allows clinicians to select the optimum FOV mode while minimizing exposure to areas outside the region of interest. The selection covers 4×4, 5×5, 8×5, 8×8, 12×9, 16×11, and 18×15 cm, spanning single tooth endodontics up to full dual arch, sinus, and bilateral TMJ evaluations.

1.9 sec
Ceph Scan
2.9 sec
CBCT Scan
4 sec
Pano Scan
1.9s Fast Ceph 2.9s Rapid CBCT 4.0s Quick Panoramic Motion-Free Imaging
Ultra-fast scan reduces patient movement artifacts, retakes, and radiation dosage.

RAPID GREEN SCAN TIME: MINIMIZING MOTION ARTIFACTS

Due to its ultra-fast scan times, the Green X 18 minimizes patient motion artifacts and enables a faster clinical workflow. It produces superb diagnostic images with cephalometric capture at 1.9 seconds, CBCT capture at 2.9 seconds, and panoramic capture in 4.0 seconds. Focusing on the highest quality of patient care, Vatech strives to improve the health and safety of your patients.

0.05mm Voxel Size Micro Resolution: Standard Dental Mode vs High-Res Endo Mode (50µm)

ENDO MODE WITH HIGH RESOLUTION (50-MICRON VOXEL)

With its 4×4 cm volume mode and 50-micron (0.05 mm) voxel size, the Endo mode optimizes treatment planning for highly-focused regions of interest. It is ideal for endodontic use because the clinician is able to achieve an extraordinary image in ultra-high resolution, revealing subtle root canals, periapical pathologies, and fine root fractures.

CST Image Reconstruction Comparison: Standard Panoramic Slice vs Insight 2.0 Multi-Layer Depth
Standard Panoramic Slice
Insight 2.0 Multi-Layer Depth

INSIGHT 2.0 WITH UPGRADED FREE FOV FEATURE

The Insight Pan takes a multi-layered panoramic image, called Insight Pan, which provides a unique in-depth look across a single focal trough. Insight 2.0 features an upgraded Free FOV feature so practitioners are able to capture and explore just the designated area of interest across variable depth slices.

ENGINEERING & DIAGNOSTIC PRECISION

SPECIFICATIONS

Green X 18 Detailed Technical Specifications
Model Designation Green X 18 (Model: PHT-75CHS)
Modality / Function CT + Pano + Ceph (Optional) + Model Scan
Focal Spot Size 0.5 mm (IEC 60336)
CT FOV Sizes 4×4, 5×5, 8×5, 8×8, 12×9, 16×11, 18×15 cm
Voxel Resolution 4×4: 0.05 mm (50 µm) | 5×5: 0.08 / 0.12 mm | 8×5 / 8×8: 0.12 / 0.2 mm | 12×9 / 16×11 / 18×15: 0.2 / 0.3 mm
Scan Times Pano: 4.0 sec / 14.1 sec | Ceph: 1.9 sec / 4.9 sec | CBCT: 2.9 sec / 9.0 sec
Gray Scale Resolution 14 Bit
Tube Voltage / Current 60 - 99 kVp / 4 - 16 mA
Unit Weight (Without CEPH) 165.9 kg (365.74 lbs - without Base) / 220.9 kg (487.00 lbs - with Base)
Unit Weight (With CEPH) 190.9 kg (420.86 lbs - without Base) / 245.9 kg (542.11 lbs - with Base)
Dimensions (Without CEPH) 1,085.0 mm (L) × 1,343.5 mm (W) × 2,315.4 mm (H - without Base) / 2,345.4 mm (H - with Base)
Dimensions (With CEPH) 1,905.5 mm (L) × 1,374.9 mm (W) × 2,315.4 mm (H - without Base) / 2,345.4 mm (H - with Base)
Motorized Column Travel 800 mm Telescopic Height Adjustment (Min Height: 1,545.4 mm)
CLINICAL FOOTPRINT & INSTALLATION

DIMENSIONS

UNIT WIDTH 1,906 mm 75 inches
UNIT DEPTH 1,375 mm 54.1 inches
MAX TELESCOPIC HEIGHT 2,345 mm 92.3 inches
TECHNICAL BLUEPRINT & CLEARANCE ENVELOPE
DIMENSIONS Technical Engineering Clearance Schematic

Clinical Case Study